EOS EMOTEC B6000 User's Guide Page 16

  • Download
  • Add to my manuals
  • Print
  • Page
    / 19
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 15
16 GB
Error display
To quickly diagnose possible errors, use the error code explanation below to ascertain the
type of error.
Error code Error
E 100 temperature sensor interruption/disconnection
E 101 temperature sensor short circuit
E 211 overheat safety shutoff interruption/disconnection
The warning symbol blinks whenever an error message is displayed, so you may
easily recognize an error.
Additional errors not displayed and their causes:
Blank display - display not backlit
Check the power supply! All three phases L1, L2, L3 must be connected to 230 V AC.
Check all fuses.
Check the microfuse on the circuit board. You may use a 100 mA / T type fuse for
replacement.
In case of breakdown, press the control
unit switch on the left part of the rocker to
the first position (switch position 0). The
unit is now completely switched off.
The control unit switch
The control unit switch can be found on the
top end of the unit. Using this
switch, you can isolate the electronics from
the mains supply in case of a breakdown.
Please note that operating the control unit
switch returns all settings to the factory
settings.
In order to switch on the light in the sauna
when the unit is switched off, press on the
left part of the rocker to the second position
(switch position II).
In order to put the unit back into operation,
switch back to the starting position (switch
position I).
Control unit switch
= unit
switched
on
= unit
switched
off
= light
switched
on
Page view 15
1 2 ... 11 12 13 14 15 16 17 18 19